Goodwe Inverter
Example 1
1type: custom:sunsynk-power-flow-card
2cardstyle: lite
3large_font: true
4title: Goodwe
5title_colour: grey
6title_size: 32px
7show_solar: true
8show_battery: true
9show_grid: true
10inverter:
11 modern: false
12 colour: grey
13 autarky: energy
14 model: goodwe_gridmode
15 three_phase: true
16battery:
17 energy: 10650
18 shutdown_soc: sensor.goodwe_shutdown_soc
19 invert_power: false
20 show_daily: true
21 max_power: 5400
22 show_absolute: false
23 auto_scale: true
24solar:
25 show_daily: true
26 display_mode: 3
27 mppts: 2
28 animation_speed: 9
29 max_power: 5400
30 pv1_name: East
31 pv2_name: West
32load:
33 show_daily: true
34grid:
35 show_nonessential: true
36 invert_grid: false
37 export_colour: green
38entities:
39 day_battery_discharge_71: sensor.today_battery_discharge
40 day_battery_charge_70: sensor.today_battery_charge
41 day_load_energy_84: sensor.today_load
42 day_pv_energy_108: sensor.today_s_pv_generation
43 inverter_voltage_154: sensor.on_grid_l1_voltage
44 inverter_voltage_L2: sensor.on_grid_l2_voltage
45 inverter_voltage_L3: sensor.on_grid_l3_voltage
46 load_frequency_192: sensor.meter_frequency
47 inverter_current_164: sensor.on_grid_l1_current
48 inverter_current_L2: sensor.on_grid_l2_current
49 inverter_current_L3: sensor.on_grid_l3_current
50 inverter_power_175: zero
51 pv1_power_186: sensor.pv1_power
52 pv2_power_187: sensor.pv2_power
53 pv_total: sensor.pv_power
54 battery_voltage_183: sensor.battery_voltage
55 battery_soc_184: sensor.battery_state_of_charge
56 battery_power_190: sensor.battery_power
57 battery_current_191: sensor.battery_current
58 essential_power: sensor.house_consumption
59 load_power_L1: sensor.load_l1
60 load_power_L2: sensor.load_l2
61 load_power_L3: sensor.load_l3
62 grid_ct_power_172: sensor.active_power_l1
63 grid_ct_power_L2: sensor.active_power_l2
64 grid_ct_power_L3: sensor.active_power_l3
65 grid_ct_power_total: sensor.active_power
66 pv1_voltage_109: sensor.pv1_voltage
67 pv1_current_110: sensor.pv1_current
68 pv2_voltage_111: sensor.pv2_voltage
69 pv2_current_112: sensor.pv2_current
70 grid_connected_status_194: sensor.grid_mode_code
71 inverter_status_59: sensor.work_mode_code
72 battery_status: sensor.battery_mode_code
73 total_pv_generation: sensor.total_pv_generation
74 battery_temp_182: sensor.battery_temperature
75 radiator_temp_91: sensor.inverter_temperature_radiator
76 dc_transformer_temp_90: sensor.inverter_temperature_air
77 day_grid_import_76: sensor.energy_buy_daily
78 day_grid_export_77: sensor.energy_sell_daily
79 remaining_solar: sensor.energy_production_today_total
80 energy_cost_buy: sensor.spot_price_buy
81 energy_cost_sell: sensor.spot_price_sell
Note
The Goodwe integration does not provide a sensor for shutdown_soc
.
A template sensor can be created using the provided depth of discharge (DOD) sensor i.e number.depth_of_discharge_on_grid
.
See example below. Note that the depth of discharge sensor name may vary depending on your HA language.
- sensor:
- name: GoodWe Shutdown SOC
unique_id: goodwe_shutdown_soc
unit_of_measurement: "%"
icon: mdi:battery-arrow-down
state: "{{100 - states('number.depth_of_discharge_on_grid') | int }}"