Goodwe Inverter
Example 1
1type: custom:sunsynk-power-flow-card
2cardstyle: lite
3panel_mode: false
4large_font: true
5title: Goodwe
6title_colour: grey
7title_size: 32px
8show_solar: true
9show_battery: true
10show_grid: true
11inverter:
12 modern: false
13 colour: grey
14 autarky: energy
15 model: goodwe_gridmode
16 three_phase: true
17battery:
18 energy: 10650
19 shutdown_soc: sensor.goodwe_shutdown_soc
20 invert_power: false
21 show_daily: true
22 max_power: 5400
23 show_absolute: false
24 auto_scale: true
25solar:
26 show_daily: true
27 display_mode: 3
28 mppts: 2
29 animation_speed: 9
30 max_power: 5400
31 pv1_name: East
32 pv2_name: West
33load:
34 show_daily: true
35grid:
36 show_nonessential: true
37 invert_grid: false
38 export_colour: green
39entities:
40 day_battery_discharge_71: sensor.today_battery_discharge
41 day_battery_charge_70: sensor.today_battery_charge
42 day_load_energy_84: sensor.today_load
43 day_pv_energy_108: sensor.today_s_pv_generation
44 inverter_voltage_154: sensor.on_grid_l1_voltage
45 inverter_voltage_L2: sensor.on_grid_l2_voltage
46 inverter_voltage_L3: sensor.on_grid_l3_voltage
47 load_frequency_192: sensor.meter_frequency
48 inverter_current_164: sensor.on_grid_l1_current
49 inverter_current_L2: sensor.on_grid_l2_current
50 inverter_current_L3: sensor.on_grid_l3_current
51 inverter_power_175: zero
52 pv1_power_186: sensor.pv1_power
53 pv2_power_187: sensor.pv2_power
54 pv_total: sensor.pv_power
55 battery_voltage_183: sensor.battery_voltage
56 battery_soc_184: sensor.battery_state_of_charge
57 battery_power_190: sensor.battery_power
58 battery_current_191: sensor.battery_current
59 essential_power: sensor.house_consumption
60 load_power_L1: sensor.load_l1
61 load_power_L2: sensor.load_l2
62 load_power_L3: sensor.load_l3
63 grid_ct_power_172: sensor.active_power_l1
64 grid_ct_power_L2: sensor.active_power_l2
65 grid_ct_power_L3: sensor.active_power_l3
66 grid_ct_power_total: sensor.active_power
67 pv1_voltage_109: sensor.pv1_voltage
68 pv1_current_110: sensor.pv1_current
69 pv2_voltage_111: sensor.pv2_voltage
70 pv2_current_112: sensor.pv2_current
71 grid_connected_status_194: sensor.grid_mode_code
72 inverter_status_59: sensor.work_mode_code
73 battery_status: sensor.battery_mode_code
74 total_pv_generation: sensor.total_pv_generation
75 battery_temp_182: sensor.battery_temperature
76 radiator_temp_91: sensor.inverter_temperature_radiator
77 dc_transformer_temp_90: sensor.inverter_temperature_air
78 day_grid_import_76: sensor.energy_buy_daily
79 day_grid_export_77: sensor.energy_sell_daily
80 remaining_solar: sensor.energy_production_today_total
81 energy_cost_buy: sensor.spot_price_buy
82 energy_cost_sell: sensor.spot_price_sell
Note
The Goodwe integration does not provide a sensor for shutdown_soc
.
A template sensor can be created using the provided depth of discharge (DOD) sensor i.e number.depth_of_discharge_on_grid
.
See example below. Note that the depth of discharge sensor name may vary depending on your HA language.
- sensor:
- name: GoodWe Shutdown SOC
unique_id: goodwe_shutdown_soc
unit_of_measurement: "%"
icon: mdi:battery-arrow-down
state: "{{100 - states('number.depth_of_discharge_on_grid') | int }}"