Goodwe Inverter

Example 1

 1type: custom:sunsynk-power-flow-card
 2cardstyle: lite
 3panel_mode: false
 4large_font: true
 5title: Goodwe
 6title_colour: grey
 7title_size: 32px
 8show_solar: true
 9show_battery: true
10show_grid: true
11inverter:
12  modern: false
13  colour: grey
14  autarky: energy
15  model: goodwe_gridmode
16  three_phase: true
17battery:
18  energy: 10650
19  shutdown_soc: sensor.goodwe_shutdown_soc
20  invert_power: false
21  show_daily: true
22  max_power: 5400
23  show_absolute: false
24  auto_scale: true
25solar:
26  show_daily: true
27  display_mode: 3
28  mppts: 2
29  animation_speed: 9
30  max_power: 5400
31  pv1_name: East
32  pv2_name: West
33load:
34  show_daily: true
35grid:
36  show_nonessential: true
37  invert_grid: false
38  export_colour: green
39entities:
40  day_battery_discharge_71: sensor.today_battery_discharge
41  day_battery_charge_70: sensor.today_battery_charge
42  day_load_energy_84: sensor.today_load
43  day_pv_energy_108: sensor.today_s_pv_generation
44  inverter_voltage_154: sensor.on_grid_l1_voltage
45  inverter_voltage_L2: sensor.on_grid_l2_voltage
46  inverter_voltage_L3: sensor.on_grid_l3_voltage
47  load_frequency_192: sensor.meter_frequency
48  inverter_current_164: sensor.on_grid_l1_current
49  inverter_current_L2: sensor.on_grid_l2_current
50  inverter_current_L3: sensor.on_grid_l3_current
51  inverter_power_175: zero
52  pv1_power_186: sensor.pv1_power
53  pv2_power_187: sensor.pv2_power
54  pv_total: sensor.pv_power
55  battery_voltage_183: sensor.battery_voltage
56  battery_soc_184: sensor.battery_state_of_charge
57  battery_power_190: sensor.battery_power
58  battery_current_191: sensor.battery_current
59  essential_power: sensor.house_consumption
60  load_power_L1: sensor.load_l1
61  load_power_L2: sensor.load_l2
62  load_power_L3: sensor.load_l3
63  grid_ct_power_172: sensor.active_power_l1
64  grid_ct_power_L2: sensor.active_power_l2
65  grid_ct_power_L3: sensor.active_power_l3
66  grid_ct_power_total: sensor.active_power
67  pv1_voltage_109: sensor.pv1_voltage
68  pv1_current_110: sensor.pv1_current
69  pv2_voltage_111: sensor.pv2_voltage
70  pv2_current_112: sensor.pv2_current
71  grid_connected_status_194: sensor.grid_mode_code
72  inverter_status_59: sensor.work_mode_code
73  battery_status: sensor.battery_mode_code
74  total_pv_generation: sensor.total_pv_generation
75  battery_temp_182: sensor.battery_temperature
76  radiator_temp_91: sensor.inverter_temperature_radiator
77  dc_transformer_temp_90: sensor.inverter_temperature_air
78  day_grid_import_76: sensor.energy_buy_daily
79  day_grid_export_77: sensor.energy_sell_daily
80  remaining_solar: sensor.energy_production_today_total
81  energy_cost_buy: sensor.spot_price_buy
82  energy_cost_sell: sensor.spot_price_sell

Note

The Goodwe integration does not provide a sensor for shutdown_soc. A template sensor can be created using the provided depth of discharge (DOD) sensor i.e number.depth_of_discharge_on_grid. See example below. Note that the depth of discharge sensor name may vary depending on your HA language.

- sensor:
    - name: GoodWe Shutdown SOC
      unique_id: goodwe_shutdown_soc
      unit_of_measurement: "%"
      icon: mdi:battery-arrow-down
      state: "{{100 - states('number.depth_of_discharge_on_grid') | int }}"