Goodwe Inverter

Example 1

 1type: custom:sunsynk-power-flow-card
 2cardstyle: lite
 3large_font: true
 4title: Goodwe
 5title_colour: grey
 6title_size: 32px
 7show_solar: true
 8show_battery: true
 9show_grid: true
10inverter:
11  modern: false
12  colour: grey
13  autarky: energy
14  model: goodwe_gridmode
15  three_phase: true
16battery:
17  energy: 10650
18  shutdown_soc: sensor.goodwe_shutdown_soc
19  invert_power: false
20  show_daily: true
21  max_power: 5400
22  show_absolute: false
23  auto_scale: true
24solar:
25  show_daily: true
26  display_mode: 3
27  mppts: 2
28  animation_speed: 9
29  max_power: 5400
30  pv1_name: East
31  pv2_name: West
32load:
33  show_daily: true
34grid:
35  show_nonessential: true
36  invert_grid: false
37  export_colour: green
38entities:
39  day_battery_discharge_71: sensor.today_battery_discharge
40  day_battery_charge_70: sensor.today_battery_charge
41  day_load_energy_84: sensor.today_load
42  day_pv_energy_108: sensor.today_s_pv_generation
43  inverter_voltage_154: sensor.on_grid_l1_voltage
44  inverter_voltage_L2: sensor.on_grid_l2_voltage
45  inverter_voltage_L3: sensor.on_grid_l3_voltage
46  load_frequency_192: sensor.meter_frequency
47  inverter_current_164: sensor.on_grid_l1_current
48  inverter_current_L2: sensor.on_grid_l2_current
49  inverter_current_L3: sensor.on_grid_l3_current
50  inverter_power_175: zero
51  pv1_power_186: sensor.pv1_power
52  pv2_power_187: sensor.pv2_power
53  pv_total: sensor.pv_power
54  battery_voltage_183: sensor.battery_voltage
55  battery_soc_184: sensor.battery_state_of_charge
56  battery_power_190: sensor.battery_power
57  battery_current_191: sensor.battery_current
58  essential_power: sensor.house_consumption
59  load_power_L1: sensor.load_l1
60  load_power_L2: sensor.load_l2
61  load_power_L3: sensor.load_l3
62  grid_ct_power_172: sensor.active_power_l1
63  grid_ct_power_L2: sensor.active_power_l2
64  grid_ct_power_L3: sensor.active_power_l3
65  grid_ct_power_total: sensor.active_power
66  pv1_voltage_109: sensor.pv1_voltage
67  pv1_current_110: sensor.pv1_current
68  pv2_voltage_111: sensor.pv2_voltage
69  pv2_current_112: sensor.pv2_current
70  grid_connected_status_194: sensor.grid_mode_code
71  inverter_status_59: sensor.work_mode_code
72  battery_status: sensor.battery_mode_code
73  total_pv_generation: sensor.total_pv_generation
74  battery_temp_182: sensor.battery_temperature
75  radiator_temp_91: sensor.inverter_temperature_radiator
76  dc_transformer_temp_90: sensor.inverter_temperature_air
77  day_grid_import_76: sensor.energy_buy_daily
78  day_grid_export_77: sensor.energy_sell_daily
79  remaining_solar: sensor.energy_production_today_total
80  energy_cost_buy: sensor.spot_price_buy
81  energy_cost_sell: sensor.spot_price_sell

Note

The Goodwe integration does not provide a sensor for shutdown_soc. A template sensor can be created using the provided depth of discharge (DOD) sensor i.e number.depth_of_discharge_on_grid. See example below. Note that the depth of discharge sensor name may vary depending on your HA language.

- sensor:
    - name: GoodWe Shutdown SOC
      unique_id: goodwe_shutdown_soc
      unit_of_measurement: "%"
      icon: mdi:battery-arrow-down
      state: "{{100 - states('number.depth_of_discharge_on_grid') | int }}"