Lux Inverter

Example 1

 1type: custom:sunsynk-power-flow-card
 2cardstyle: lite
 3show_solar: true
 4inverter:
 5  model: lux
 6battery:
 7  show: true
 8  energy: 12800
 9  shutdown_soc: 1
10  show_daily: true
11  invert_power: true
12solar:
13  show_daily: true
14  mppts: 2
15  pv1_name: Rear
16  pv2_name: Front
17load:
18  show_daily: true
19grid:
20  show_daily_buy: true
21  show_daily_sell: true
22  show_nonessential: false
23  invert_grid: true
24  additional_loads: 2
25entities:
26  inverter_voltage_154: sensor.lux_grid_voltage_live
27  load_frequency_192: sensor.lux_grid_frequency_live
28  inverter_current_164: sensor.inverter_output_current
29  inverter_status_59: sensor.lux_status
30  inverter_power_175: sensor.lux_battery_flow_live
31  day_battery_charge_70: sensor.lux_battery_charge_daily
32  day_battery_discharge_71: sensor.lux_battery_discharge_daily
33  battery_voltage_183: sensor.lux_battery_voltage_live
34  battery_soc_184: sensor.lux_battery
35  battery_power_190: sensor.lux_battery_flow_live
36  battery_current_191: sensor.lux_battery_capacity_ah
37  grid_power_169: sensor.lux_grid_flow_live
38  day_grid_import_76: sensor.lux_power_from_grid_daily
39  day_grid_export_77: sensor.lux_power_to_grid_daily
40  grid_ct_power_172: sensor.lux_grid_flow_live
41  day_load_energy_84: sensor.lux_power_from_inverter_to_home_daily
42  essential_power: sensor.lux_home_consumption_live
43  nonessential_power: none
44  aux_power_166: sensor.aux_output_power
45  day_pv_energy_108: sensor.lux_solar_output_daily
46  pv_total: sensor.lux_solar_output_live
47  pv1_power_186: sensor.lux_solar_output_array_1_live
48  pv2_power_187: sensor.lux_solar_output_array_2_live
49  pv1_voltage_109: sensor.lux_solar_voltage_array_1_live
50  pv1_current_110: none
51  pv2_voltage_111: sensor.lux_solar_voltage_array_2_live
52  pv2_current_112: none
53  radiator_temp_91: sensor.lux_radiator_1_temperature_live
54  dc_transformer_temp_90: sensor.lux_radiator_2_temperature_live
55  remaining_solar: sensor.forecast_remaining_today
56  energy_cost: sensor.octopus_energy_electricity_20e5081533_2380002009185_current_rate

Example 2 using the lxp-bridge integration (https://github.com/celsworth/lxp-bridge)

 1type: custom:sunsynk-power-flow-card
 2cardstyle: lite
 3show_solar: true
 4inverter:
 5  model: lux
 6battery:
 7  energy: 12800
 8  shutdown_soc: 20
 9  show_daily: true
10  invert_power: true
11solar:
12  show_daily: true
13  mppts: 2
14  pv1_name: PV1
15  pv2_name: PV2
16load:
17  show_daily: true
18grid:
19  show_daily_buy: true
20  show_daily_sell: true
21  show_nonessential: false
22  invert_grid: true
23  additional_loads: 0
24entities:
25  inverter_voltage_154: sensor.lxp_baXXXXXXXX_grid_voltage
26  load_frequency_192: sensor.lxp_baXXXXXXXX_eps_frequency
27  inverter_current_164: NONE
28  inverter_status_59: NONE
29  inverter_power_175: sensor.lxp_baXXXXXXXX_inverter_power
30  day_battery_charge_70: sensor.lxp_baXXXXXXXX_battery_charge_today
31  day_battery_discharge_71: sensor.lxp_baXXXXXXXX_battery_discharge_today
32  battery_voltage_183: sensor.lxp_baXXXXXXXX_battery_voltage
33  battery_soc_184: sensor.lxp_baXXXXXXXX_battery_percentage
34  battery_power_190: sensor.lxp_baXXXXXXXX_battery_power_discharge_is_negative
35  battery_current_191: NONE
36  grid_power_169: sensor.lxp_baXXXXXXXX_grid_power_export_is_negative
37  day_grid_import_76: sensor.lxp_baXXXXXXXX_energy_from_grid_today
38  day_grid_export_77: sensor.lxp_baXXXXXXXX_energy_to_grid_today
39  grid_ct_power_172: NONE
40  day_load_energy_84: sensor.lxp_baXXXXXXXX_energy_of_inverter_today
41  essential_power: sensor.lxp_baXXXXXXXX_inverter_power
42  nonessential_power: NONE
43  aux_power_166: NONE
44  day_pv_energy_108: sensor.lxp_baXXXXXXXX_pv_generation_today
45  pv_total: sensor.lxp_baXXXXXXXX_power_pv_array
46  pv1_power_186: sensor.lxp_baXXXXXXXX_power_pv_string_1
47  pv2_power_187: sensor.lxp_baXXXXXXXX_power_pv_string_2
48  pv1_voltage_109: sensor.lxp_baXXXXXXXX_voltage_pv_string_1
49  pv1_current_110: NONE
50  pv2_voltage_111: sensor.lxp_baXXXXXXXX_voltage_pv_string_2
51  pv2_current_112: NONE
52  radiator_temp_91: sensor.lxp_baXXXXXXXX_radiator_1_temperature
53  dc_transformer_temp_90: sensor.lxp_baXXXXXXXX_radiator_2_temperature
54  remaining_solar: sensor.forecast_remaining_today
55  energy_cost: NONE

Note

Replace baXXXXXXXX with your wifi dongle number